[D27]Data Center Environmental Monitoring
by Jim Furness, Jim

Many modern data logger models offer long operation on internal batteries coupled with multi channel universal input capability. This makes them ideal for use in the field with a variety of environmental sensors. The basic data logger inputs required for these sensors are listed below:

Data Logger Temperature Sensor Inputs

The three main types of temperature sensors are thermocouples, PT100 sensors and thermistors. Thermocouples require a data logger with high resolution and cold junction compensation. Thermocouples do not require external power making them ideal for use with data logger installations in remote locations. Thermistors are low cost and accurate, but are non linear so the data logger needs an internal look up table to read these devices accurately. PT100 sensors are very accurate, but as they are three wire devices many low cost data logger models are not compatible.

Data Logger Rain Gauge Inputs

A rain gauge is a barrel shaped device with a rain collector. The collector funnels the rain water onto a tipping bucket sensor. When the bucket fills up it tips, triggering a pulse from a reed switch to measure 0.2 of a millimeter of rainfall. A data logger must have a pulse input to work with a rain gauge.

Data Logger Inputs for Solar Radiation Sensors

Whilst many low cost data logger models can work with temperature sensors and rain gauges, the very low voltage output of solar radiation sensors can present a problem. With a typical range of 0-20 mV to represent a range of 0-2000 WM2 a data logger needs a very low measurement range and high resolution to take meaningful readings.

Data Logger inputs for Water Level Sensors

Water level sensors are usually submersible pressure sensor types or ultrasonic non contact. As most pressure based depth sensors require excitation the data logger needs to be able to power the sensor. Many data logger models have a five volt supply available for this type of sensor. For use with ultrasonic level sensors the data logger needs to be able to power a 4-20mA loop.

Data Logger Inputs for Wind Sensors

These are available with voltage, mA and serial outputs. Whilst most data logger types can handle voltage and current inputs few are able to read serial devices. The new generation of Omni Instruments data logger models support the serial protocols used by the latest wind sensors.

So it can be seen that for environmental monitoring applications it is important to select a data logger with multi channel input capability which is able to support a wide range of sensor inputs

Omni Instruments has many years of experience of providing data logger equipment for these applications and can also supply compatible sensors.

Jim Furness has sinced written about articles on various topics from Information Technology, Computers and The Internet and Information Technology. . Jim Furness's top article generates over 1900 views. to your Favourites.
EditorialToday IT Hardwares has 2 sub sections. Such as Computer Guide and Hardware. With over 20,000 authors and writers, we are a well known online resource and editorial services site in United Kingdom, Canada & America . Here, we cover all the major topics from self help guide to A Guide to Business, Guide to Finance, Ideas for Marketing, Legal Guide, Lettre De Motivation, Guide to Insurance, Guide to Health, Guide to Medical, Military Service, Guide to Women, Pet Guide, Politics and Policy , Guide to Technology, The Travel Guide, Information on Cars, Entertainment Guide, Family Guide to, Hobbies and Interests, Quality Home Improvement, Arts & Humanities and many more.